A dryer that runs long or leaves clothes damp is most often short of airflow, or set to a cycle or load that dries slowly. A blocked lint filter or vent is also a fire risk, which is why makers and fire agencies cover it. This guide follows the CPSC, the U.S. Fire Administration and Whirlpool, Samsung and LG support pages, and uses only what you can see and change without tools. The sources are US pages. Rules, models and venting standards outside the US may differ.
What is normal
Some cycles run longer on purpose. Whirlpool says its EcoBoost option, which is on by default for the Regular/Normal cycle on its models that have it, uses lower heat and adds about 40 minutes. Samsung says Eco Dry makes parts of the cycle, such as the start, run without heat. Air Dry and Fluff cycles add no heat at all (Whirlpool).
Possible causes
- A lint filter that is clogged or coated with residue from softener sheets (Whirlpool, CPSC).
- A vent or exhaust duct that is blocked, kinked, crushed or too long. Whirlpool calls poor ventilation a leading cause of long dry times, and Samsung says a blocked vent is the likely cause when the dryer heats but clothes stay damp (Whirlpool, Samsung US, CPSC).
- A cycle that does not add much heat, such as Air Dry, Fluff or an eco option (Whirlpool, Samsung US).
- A load that is too large, too mixed, or not spun enough in the washer first (Whirlpool, LG).
- A new dryer connected to old venting that has not been cleaned (Whirlpool).
- A dryer that is not heating at all, which is a different problem: see the not-heating guide.
Safe checks, in order
No tools, no panels, nothing disconnected.
- Before you run any cycle. Our precautions before any cycle is started or run. Make sure the lint filter is clean and in place and the area around the dryer is dry and clear. If you smell gas, use the emergency steps at the top of this page. If there is smoke, a burning smell or visible damage, do not run the dryer and call a qualified technician.
- Clean the lint filter now. CPSC says to clean it before or after every load, and the U.S. Fire Administration says before and after each cycle. Never run the dryer without the filter. If softener sheets leave a film on the filter, Whirlpool says to wash it with warm water and a soft brush and let it dry completely (CPSC, USFA, Whirlpool).
- Check the cycle and options. Switch from Air Dry, Fluff or an eco option to an automatic or Regular cycle if you want faster, hotter drying, once the precautions above are met. Whirlpool says to use an automatic cycle for best results (Whirlpool, Samsung US).
- Check the load size. Whirlpool says the drum should be about one-half to three-quarters full so clothes can tumble. LG says about halfway. Both are the makers' figures for their own dryers, so check your manual. LG also says a very small load can make the dryer stop on its own after about 10 minutes in automatic mode (Whirlpool, LG).
- Make sure the washer spun the load first. LG says laundry that did not finish spinning takes a long time to dry (LG).
- Split mixed loads. Whirlpool says to dry similar fabrics together and to dry bulky items such as comforters alone, pausing to shake them out (Whirlpool).
- Check the outside vent while the dryer is running. The dryer must be running for this, so only once the precautions above are met. Then stand outside and see whether air is coming out and whether the hood flap opens. CPSC says that if air is not escaping, the vent or duct may be blocked. Look only. Do not reach into the vent and do not disconnect any duct (CPSC, Whirlpool).
- Notice the pattern. Warm but damp clothes after a full cycle, a warm or humid laundry area, or lint building up around the door are signs of restricted airflow (Whirlpool, Samsung US). If you see them, go to the technician list below.
When you need a technician
- Little or no air at the outside vent, or a hood flap that does not open. Have a qualified professional or dryer vent cleaning service inspect and clean the vent. Whirlpool says exhaust venting should be cleaned every one to two years or when drying performance drops.
- Clothes still damp after the checks above, or cycles that stay very long.
- Plastic or foil accordion-type ducting behind the dryer. CPSC says to replace it with rigid or corrugated semi-rigid metal duct. That is work for an installer or professional.
- Lint built up around the door or behind the dryer. CPSC says to have a qualified service person clean the inside of the dryer periodically. Do not pull the dryer out or open it yourself.
- A burning smell, smoke, sparks, or a dryer that is much hotter than usual to the touch: stop using it and call a qualified technician. If you see smoke or fire, leave and call your local emergency number. This is not a question of comfort.
- A code on the display. Use the error code lookup and your manual.
Where makers differ
Whirlpool says to unplug the dryer and check or clean the vent hose behind it, and CPSC says clearing a blockage may mean disconnecting the duct. This guide leaves those steps out because they involve unplugging and moving the dryer. Samsung describes a built-in vent blockage test run from the control panel on its dryers, with button combinations that depend on the model, so use Samsung's page or your manual. Whirlpool says many dryers work best with a total equivalent vent length under 35 feet, with each 90-degree elbow adding resistance. That is an installation limit for your model, not a number to measure yourself.
Sources
- CPSC: Overheated clothes dryers can cause fires
- U.S. Fire Administration: Clothes dryer fire safety
- Whirlpool: Dryer is not drying or experiencing long dry times
- Samsung US: Clothes are not dry after using Samsung dryer
- LG US: Laundry is not drying well (electric dryer)